Kingswear Signal Box
Lever Leads
Based on SRS documentation with some suggested improvements.
No. | Nomenclature Thoughts | ||
---|---|---|---|
1 | No.1 Platform Starting | 18 OR 6 OR 19 | |
2 | No.2 Platform Starting | 12 | |
3 | No.2 Platform Startin To Main | 21 18 OR 21 6 OR 21 19 | |
4 | Disc For 20A | 21 20 18 OR 21 20 6 OR 21 20 19 | |
5 | Disc At 24A | NIL OR 24 6 OR 24 19 | |
6 | Up Main Starting | 28 | |
7 | Up Main Advance Starting | - | |
8 | - | - | |
9 | - | - | |
10 | - | - | |
11 | Disc For 13B | 13 12 OR 14 13 12 | |
12 | FPL For 13B | - | |
13 | Up No.2 Platform Facing / Down Loop | - | |
14 | Compound Points In Down Loop | 13 | |
15 | Disc Starting From Down Loop Sidings | 14 | |
16 | Disc Starting From Down Loop | 13 | |
17 | Disc Starting From Turntable | - | |
18 | Up Main Starting To Up Sidings | 27 28 | |
19 | Up Main Starting To Down Siding | 29 28 | |
20 | Down No.2 Platform Facing / Down Loop | 21 | |
21 | Down Main Facing / No.2 Platform | - | |
22 | Interlocking Lever For G.F. | - | |
23 | Disc Starting From Up Siding | - | |
24 | No.1 Platform Facing / Up Loop | - | |
25 | FPL's for 20B 21 & 24B | - | |
26 | - | - | |
27 | Up Main Facing / Up Sidings | - | |
28 | FPL's For 27A & 29A | - | |
29 | Up Main Facing / Down Siding | - | |
30 | Disc At 21 | 20 21 25 OR 24 25 | |
31 | - | - | |
32 | - | - | |
33 | - | - | |
34 | Down Main Inner Home To No.2 Platform | 21 25 | |
35 | Down Main Inner Home To No.1 Platform | 25 | |
36 | Disc At 27B & 27C | NIL OR 27 30 OR 27 34 OR 27 35 | |
37 | Disc For 29B | 29 30 OR 29 34 OR 29 35 | |
38 | Down Main Home | 25 |